Cabletron Systems 6A000 Switch User Manual


 
Appendix B-6 SmartCell 6A000 User Guide
MIB, SMI, MIB Files and Internet MIB Hierarchy Agent Support
Note Along with the MIBs, the diskette also contains a README file and the release
note.
B.1.7 MIB Exceptions
With the current implementation of MIB files, conformance to ATM standards for the SmartCell 6A000 ATM switch
includes the following exceptions.
Non-Conformance
atmInterfaceIlmiVpi — Read-only
atmInterfaceIlmiVci — Read-only
aal5VccTable — Not supported
atmSvcVcCrossConnectRowStatus Set — Not supported
atmConfigSigType — The values given below are not supported:
-
ituDss2
-
atmfBici2Dot0
znIpAtmClientDDVcType — Accepts only pvc(2) in sets
lecMulticastSendType — Accepts only best effort (1)
lecMulticastSendAvgRate — Accepts values only up to 370370
lecMulticastSendPeakRate — Accepts values only up to 370370
leArpEntryType — Accepts only staticVolatile (4) and staticNonVolatile (5)
lesControlTimeout — Read-only
Not Supported
The following MIB objects are not supported. If used, these objects return either the value zero or the message, “Not
supported.”
atmInterfaceMaxVpcs
atmInterfaceConfVpcs
atmInterfaceDs3PlcpTable
atmInterfaceTCTable
atmVplTable
atmVpCrossConnectIndexNext
atmVpCrossConnectTable
atmSvcVpCrossConnectTable
atmSigSupportTable
atmSigDescrParamTable