Appendix B-6 SmartCell 6A000 User Guide
MIB, SMI, MIB Files and Internet MIB Hierarchy Agent Support
Note Along with the MIBs, the diskette also contains a README file and the release
note.
B.1.7 MIB Exceptions
With the current implementation of MIB files, conformance to ATM standards for the SmartCell 6A000 ATM switch
includes the following exceptions.
Non-Conformance
•
atmInterfaceIlmiVpi — Read-only
•
atmInterfaceIlmiVci — Read-only
•
aal5VccTable — Not supported
•
atmSvcVcCrossConnectRowStatus Set — Not supported
•
atmConfigSigType — The values given below are not supported:
-
ituDss2
-
atmfBici2Dot0
•
znIpAtmClientDDVcType — Accepts only pvc(2) in sets
•
lecMulticastSendType — Accepts only best effort (1)
•
lecMulticastSendAvgRate — Accepts values only up to 370370
•
lecMulticastSendPeakRate — Accepts values only up to 370370
•
leArpEntryType — Accepts only staticVolatile (4) and staticNonVolatile (5)
•
lesControlTimeout — Read-only
Not Supported
The following MIB objects are not supported. If used, these objects return either the value zero or the message, “Not
supported.”
•
atmInterfaceMaxVpcs
•
atmInterfaceConfVpcs
•
atmInterfaceDs3PlcpTable
•
atmInterfaceTCTable
•
atmVplTable
•
atmVpCrossConnectIndexNext
•
atmVpCrossConnectTable
•
atmSvcVpCrossConnectTable
•
atmSigSupportTable
•
atmSigDescrParamTable