Cabletron Systems 6A000 Switch User Manual


 
SmartCell 6A000 User Guide 3-7
,6˜3¦F•˜":1˜"m=˜/"2' %•F"›amV˜"m˜'h¤d"›F=˜/"2˜˜
This is analogous to a phone company that supports a communication system. Even though the phone company
maintains the circuits, a call to the phone company itself cannot be made unless the phone company has its own number
and connection on its own phone system. Similarly, VLAN membership (and the reachability) of a SmartCell 6A000
on any particular VLAN depends upon whether the SmartCell 6A000 has a local client connection for that VLAN.
Clients are created using the command
add laneclient for LAN emulation, and add ipatmclient for IP over ATM.
For example, the following command adds a switch client to the ELAN elan1:
SmartCell ZX# add laneclient
ClientNumber(0) : 1
LanName(ELAN001) : elan1
ServerType(LECS) :
ServerAddress() :
IPAddress() : 128.213.77.95
NetMask(255.255.0.0) :
MTU(1516) :
SmartCell ZX#
Prior to creating this local client connection, end devices could communicate with each other through elan1, but they
could not communicate with the SmartCell 6A000.