2-8 SmartCell 6A000 User Guide
Using the Console Switch Installation and Setup
s¥ After you enter these parameters and reboot the switch, log off the local console connection. Perform
additional configuration steps over your network using a telnet connection.
2p›F Only one console connection is allowed at any time. To reach the SmartCell
6A000 through telnet, you must exit the local terminal connection by entering the
exit command.
The following is an example of the initial configuration session:
SmartCell ZX Version 2.1 (c) Cabletron Inc.
password:: admin
<
¸
admin" is the default password
The current user is Administrator
Could not find setup file
Running Setup Automatically
SwitchName() : My_6A000
< a switch name
IPAddress(0.0.0.0) : 210.160.77.254
< an IP address
IPNetMask(255.0.0.0) : 255.255.255.0
< a subnet mask
Confirm(y/n)?:y
Changing IP Address on System. Telnet session (if any) will be lost.
SmartCell ZX #
Before continuing to chapter 3, “IP over ATM and LANE,” read the following sections for information about
U Using the SmartCell 6A000 console
U Installing and getting started with the Windows-based SmartSwitch ATM Administrator application
2.5 USING THE CONSOLE
Use the SmartCell 6A000 console interface to configure and manage your switch. The following is a description of the
console interface and its operation.
2.5.1 Console Commands
2p›F For detailed descriptions of console commands, see the SmartCell 6A000/ZX-250
Reference Manual.
All console commands use the syntax:
operator switch-attribute [<parameter 1> <parameter 2>... <parameter n>]
Where the operator is one of the following:
show ( display): Show the current values used by a switch-attribute.
add ( create): Add a new instance of a switch-attribute.
delete ( remove): Delete an instance of a switch-attribute.
modify ( set): Change the values that currently define a switch-attribute.