Cabletron Systems 6A000 Switch User Manual


 
2-10 SmartCell 6A000 User Guide
Using the Console Switch Installation and Setup
2p›F When you accept the (all) default for show, the information displayed is often
abridged.
2.5.2 Console Time-out
The console can be configured to exit if it does not sense a key stroke within a defined length of time. By default, the
SmartCell 6A000 is set to never time-out (value = 0). To activate the time-out feature, use the
set ConsoleTimeOut
command to adjust the time-out period:
SmartCell ZX # set consoletimeout
Timeout(0) : 30 <Will time-out in 30 minutes without input
Confirm (y/N)? : y
SmartCell ZX #
2.5.3 Creating an Alias
Use the add alias command to create shorter or easier-to-remember names for command lines. For example:
SmartCell ZX # add alias
AliasName() : traffic
AliasedString() : set switchtrafficcongestion
SmartCell ZX #
The above example creates an alias (traffic) that can be entered in place of the command set
SwitchTrafficCongestion
. For example:
SmartCell ZX # traffic
Queue1EFCIThreshold(4096) :
Queue2EFCIThreshold(4096) :
Queue3EFCIThreshold(4096) :
Queue4EFCIThreshold(4096) :
LowEPDWatermark(10922) :
HighEPDWatermark(21845) :
RMCellMarkingEnable(1) :
EFCIMarkingEnable(1) :
SmartCell ZX #
Enter the show alias command to display a list of all defined aliases and the command lines to which they correspond.
:SmartCell ZX # show alias
AliasName(ALL) :
Alias List
==============================================================================
Index Alias Name : Aliased Command
1 PING : Start ping
2 xxx : show portconfig
3 traffic : set switchtrafficcongestion
SmartCell ZX #