Cabletron Systems 6A000 Switch User Manual


 
4-12 SmartCell 6A000 User Guide
PVC Connections Switch Administration
4.5.1 Point-to-Point PVCs
The procedure for setting up a PVC connection between two end nodes through the SmartCell 6A000 consists of
specifying the ports and the virtual path and virtual channel identifiers (VPI and VCI).
1. Use add trafficdescriptor to define a traffic descriptor to use with the PVC
SmartCell ZX # add trafficdescriptor
TrafficType(UBR) : cbr
TrafficDescriptorType(2) :
PCRCLP01(100) :
PCRCLP0(0) :
SCRCLP01(0) :
SCRCLP0(0) :
MBSCLP01(0) :
MBSCLP0(0) :
QOSCLASS(1) :
AalType(5) :
SmartCell ZX #
For this example, we specify CBR as the traffic type, then take the remaining defaults. Enter the show
trafficdescriptor
command to obtain the index number of the new traffic descriptor. In this example, the index
number is two (2).
SmartCell ZX # show trafficdescriptor
==================================================================================
TD# Traff Desc QoS Peak Cell Rate Sust Cell Rate Max Burst Size Aal
Type Type (Kb/s) (Kb/s) (Kb/s) Type
CLP_0 CLP_0+1 CLP_0 CLP_0+1 CLP_0 CLP_0+1
==================================================================================
2 CBR 2 1 0 100 0 0 0 0 5
176 NRTVBR 2 1 0 1585 0 0 0 0 5
SmartCell ZX #
2. Use add pvc to create the PVC; specify the ports through which the connection is established, the
VPI/VCI pair to use with each port, and the traffic descriptor to use.
SmartCell ZX # add pvc
ConnType(PTP) :
LowPortID() : c1
<we specify port c1
LowVPI() : 0
<we specify VPI = 0
LowVCI() : 100
<we use VCI = 100
HighPortID() : b2
<we specify port b2
HighVPI() : 0
HighVCI() : 100
FwdTrafficDescriptorIndex() : 2
<we use our created traffic descriptor
BkwTrafficDescriptorIndex() : 2
<we use our created traffic descriptor
SmartCell ZX #
The example above creates a PVC between ports C1 and B2 with VPI/VCI = 0/100.
3. Plug the end nodes into the specified SmartCell 6A000 ports (C1 and B2).
4. Configure each end node with the proper IP address, subnet mask, and VPI/VCI pair = 0/100.
The end nodes can communicate with each other through the point-to-point PVC connection.
4.5.2 Point-to-Multipoint PVCs
Instructions in this section describe how to set up a point-to-multipoint connection through your SmartCell 6A000.
Example: Create a point-to-multipoint connection between a broadcasting workstation on port A1 and three other
workstations connected to ports B2, B3, and C1.