Chapter 5: Local Management
5-76 6H128-08 and 6H129-08 User’s Guide
Reboot After Download (Modifiable only when RUNTIME is chosen)
This field notifies the user that the 6H12X-08 will reboot after the
download is complete. If a RUNTIME Download is performed this field
toggles between YES and NO. If YES is selected, the module reboots
after the download is completed. If NO is selected the module will
continue using the existing the firmware image. The module stores the
new firmware image in FLASH memory. When the module or 6C105
chassis is reset, the module will boot from FLASH memory using the new
image.
TFTP Gateway IP Addr (Selectable)
This field shows the IP address of the TFTP gateway server defined in the
General Configuration screen in Section 5.15.4.
Last Image Server IP (Read-only)
This field shows the IP address of the server used for the previous FLASH
Download.
Last Image File Name (Read-only)
This field shows the complete path and file name of the last image
downloaded to FLASH.
Download Server IP (Selectable)
The IP address of the TFTP server to be used for the FLASH download is
entered in this field.
Download File Name (Selectable)
The complete TFTP Server path and file name of the new image is entered
in this field.
5.22.1 Image File Download Using TFTP
Set the 6H12X-08 to download to FLASH using TFTP as follows:
1. Use the arrow keys to highlight the Download Method field.
2. Use the SPACE bar to select TFTP.
3. Use the arrow keys to highlight the TFTP Gateway IP Addr field.
NOTE
If TFTP or RUNTIME is selected as the download method
(Figure 5-28), the following two additional fields display: