Cabletron Systems 6H128-08 Switch User Manual


 
Chapter 5: Local Management
5-94 6H128-08 and 6H129-08 User’s Guide
Undersized Pkts (Read-only)
The Undersized Pkts field displays the number of frames received whose
size was less than the minimum Ethernet frame size of 64 bytes, not
including preamble, but have a valid CRC.
Oversized Pkts (Read-only)
The Oversized Pkts field displays the number of frames received whose
size exceeded 1518 data bytes, not including preamble, but have a valid
CRC.
Fragments (Read-only)
This field displays the number of received frames that are not the
minimum number of bytes in length or received frames that had a bad
Frame Check Sequence (FCS), were less than 64 bytes in length
(excluding framing bits, but including FCS bytes), and have an invalid
CRC.
Jabbers (Read-only)
This field displays the total number of frames that were greater than 1518
bytes and had either a bad FCS or a bad CRC.
Total Packets (Read-only)
This field displays the total number of frames (including bad frames,
broadcast frames, and multicast frames) received on this interface.
Total Octets (Read-only)
This field displays the total number of octets (bytes) of data, including
those in bad frames, received on this interface.
64 Octets (Read-only)
Displays the total number of frames including bad frames, received that
were 64 bytes in length (excluding framing bits, but including FCS bytes).
65 - 127 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 65 and 127 bytes in length (excluding framing bits, but
including FCS bytes).
NOTE
It is normal for the Fragments field to increment. This is
because the RMON agent increments the field when runts are
detected (which are normal occurrences due to collisions) and