Candle-lite DB2 Network Card User Manual


 
Getting Started 23
Setting Logon Options
Application ID The OMEGAMON II classic interface VTAM mode application
identifier.
DB2 subsystem The DB2 subsystem ID that you want to monitor.
Logical rows The number of logical rows (100–9999).
Migrate Profile from
OMEGAMON
Enter Yes if you want to migrate a classic interface user profile to a
CUA subsystem profile. Use this feature only to provide a set of
values to use as a starting point for customizing the CUA subsystem
profile.
When you migrate classic threshold values, they become CUA critical
values.
If a CUA exception is set to trip when it exceeds its threshold, then
the warning threshold is set to 80% of the critical threshold. If a CUA
exception is set to trip when it falls below its threshold, then the
warning threshold is set to 125% of the critical threshold.
For exceptions that are not associated with threshold values, the CUA
critical value is set to on, and the warning value is set to off. If the
classic STATE= value is ON, the CUA monitor value is YES. If the
value for STATE= is OFF, the monitor value is NO.
OMEGAMON Profile to
Migrate
The suffix of the profile you want to migrate from the classic
OMEGAMON II system.
User Data Additional classic interface options, such as USER=cc.
Note:
During normal operations, this field should be left blank.
Field Description