Datalogic Scanning 4420 Scanner User Manual


 
Bar Code Parameters
Product Reference Guide F-21
User ID
Specifies the symbology identifier
(if any) that is sent when parameter
Send Code ID (Index 0025) is set to
3.
ASCII code zero (null) is used
to indicate that an identifier is not to
be sent for the symbology
0
1
2
5
Any
single
ASCII
charac-
ter
(00 =
Off)
'X' 'X' 'X'
99
Universal Product Code-A (UPC-
A)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the UPC-A sym-
bology.
0
5
0
0
On or
Off
Off On On
99
Enable
Aggres-
sive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0
5
0
1
On or
Off
Off On Off
9
Send
Check
Digit
Includes check digit in the label
which is transmitted.
0
5
0
2
On or
Off
Off On Off
99
Send Sys-
tem Digit
Includes the system digit in the
label transmission. For UPC-A, the
system digit is always zero.
0
5
0
3
On or
Off
Off On On
99
Convert
UPC-A to
EAN-13
Instructs the decoder to expand
UPC-A labels to their EAN-13
equivalents. Any EAN-13 parame-
ters will then apply to the result.
0
5
0
4
On or
Off
Off On Off
9
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er