Datalogic Scanning 4420 Scanner User Manual


 
Bar Code Parameters
Product Reference Guide F-23
Convert
UPC-E to
UPC-A
Instructs the decoder to expand
UPC-E labels to their UPC-A equiv-
alents. Any UPC-A parameters will
then apply to the result.
0
5
0
C
On or
Off
Off On Off
99
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
5
2
2
01 - 04 01 02 01
9
User ID
Specifies the symbology identifier
(if any) that is sent by the decoder
when parameter Send Code ID
(Index 0025) is set to 3.
ASCII
code zero (null) is used to indicate
that an identifier is not to be sent for
the symbology.
0
5
2
3
Any
single
ASCII
charac-
ter
(00 =
Off)
'E' 'E' 'E'
99
UPC/EAN Extensions
Enter 1 for On
and 0 for Off.
Enable 2-
Digit
Extensions
Requires a 2 digit extension (sup-
plemental label) to be verified for a
successful decode of a label.
0
5
1
C
On or
Off
Off On On
99
Enable 5-
Digit
Extensions
Requires a 5 digit extension (sup-
plemental label) to be verified for a
successful decode of a label.
0
5
1
D
On or
Off
Off On On
99
Enable
Code 128
Extensions
Enables/disables Code 128 exten-
sions.
0
5
1
E
On or
Off
Off On On
9
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er