Datalogic Scanning 4420 Scanner User Manual


 
Bar Code Parameters
Product Reference Guide F-27
Compos-
ite
User ID
Specifies the symbology identifier
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is
set to 3.
ASCII code zero (null) is
used to indicate that an identifier is
not to be sent for the symbology.
0
A
2
B
Any sin-
gle
ASCII
charac-
ter (00 =
Off)
‘b’ ‘b’ ‘b’
NOTE: For the 2D Imager, RSS-Expanded User Code ID is used for Composite
Maxicode
Enter 1 for On
and 0 for Off.
Maxicode
Enable
Enables/disables the Maxicode
symbology.
0
B
0
8
On or
Off
Off On On
9
Minimum
Label
Length
Set the minimum bar code label
length to be less than or equal to
maximum label length.
0
B
2
4
1 - 138 1 138 1
9
Maxicode
Maximum
This feature specifies the maxi-
mum allowable length of a label.
The length includes check and
data characters, if applicable.
Maximum Label Length should be
greater than or equal to Minimum
Label Length.
0
B
2
5
1 - 138 1 138 138
9
Maxicode
User ID
Specifies the symbology identifier
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is
set to 3.
ASCII code zero (null) is
used to indicate that an identifier is
not to be sent for the symbology.
0
B
2
7
Any sin-
gle
ASCII
charac-
ter (00 =
Off)
‘W’ ‘W’ ‘W’
9
Code Parameter/ Description
I.
D.
#
Accept
able
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er