Dell 9.7(0.0) Laptop User Manual


  Open as PDF
of 1684
 
Example
Dell# show alarms
-- Minor Alarms --
Alarm Type Duration
----------------------------------------------
RPM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 1 PEM A failed or rmvd 7 hr, 37 min
SFM 2 PEM A failed or rmvd 7 hr, 37 min
SFM 3 PEM A failed or rmvd 7 hr, 37 min
SFM 4 PEM A failed or rmvd 7 hr, 37 min
SFM 5 PEM A failed or rmvd 7 hr, 37 min
SFM 6 PEM A failed or rmvd 7 hr, 37 min
SFM 7 PEM A failed or rmvd 7 hr, 36 min
stack-unit 1 PEM A failed or rmvd 7 hr, 36 min
stack-unit 4 PEM A failed or rmvd 7 hr, 36 min
only 8 SFMs in chassis 7 hr, 35 min
-- Major Alarms --
Alarm Type Duration
----------------------------------------------
No major alarms
Dell#
show command-tree
Display the entire CLI command tree, and optionally, display the utilization count for each command and
its options.
Syntax
show command-tree [count | no]
Parameters
count Display the command tree with a usage counter for each
command.
no Display all of the commands that may be preceded by the
keyword no, which is the keyword used to remove a
command from the running-configuration.
Defaults none
Command
Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
Control and Monitoring
125