Cabling Your Cluster Hardware 19
3
Connect the VHDCI connector of the second SCSI cable (see Figure 2-2) to the channel 0
connector on the cluster-enabled PERC RAID adapter in the second PowerEdge system, and
then tighten the retaining screws.
4
Connect the SCSI connector B (see Figure 2-1) on the back of the PowerVault 22
x
S storage
system to the 68-pin connector on the second SCSI cable (see Figure 2-2), and tighten the
retaining screws.
NOTE: If the PowerVault 22xS storage system is disconnected from the cluster, it must be
reconnected to the same channel on the same PERC RAID adapter for proper operation.
Figure 2-2. Cabling a Clustered System With One PowerVault 22xS Storage System
PowerVault 22xS
storage system
SCSI connections from
channel 0 on each
cluster-enabled
PERC RAID adapter
VHDCI
node 1
node 2
PERC RAID
adapter
shared storage
connector A(68-pin connector)
shared storage connector B
(68-pin connector)
se500wbk1.book Page 19 Thursday, June 16, 2005 4:19 PM