Dialogic DSI SPCI Network Interface Boards Network Router User Manual


 
6 Message Reference
68
timeslot
The timeslot number on the T1/E1 line interface unit on which the fixed data
is transmitted. The valid range for timeslot is 1 to 31 for an E1 interface and
1 to 24 for a T1 interface.
pattern
The value of the fixed data to be generated. The value must be in the range 0
to 255. Typical values are 0xff for an "all ones" idle pattern, or 0x2a for an
ITU-T E1 idle pattern.
Status Response
The confirmation message (if requested) indicates success by status of zero.
On error, the following status values can be found in the confirmation
message.
Value Mnemonic Description
0xd2 MVIP_INVALID_STREAM Invalid stream specified in listen request.
0xd3 MVIP_INVALID_TIMESLOT Invalid timeslot specified in listen request.
0xff None Fixed pattern generation request failed.
6.3.9 Reset Switch Request
Synopsis:
Resets the digital switch to its default state in accordance with the current
board configuration.
Message Format:
MESSAGE HEADER
Field Name Meaning
type MVD_MSG_RESETSWX (0x7e00)
id
0
src
Sending Module ID
dst MVD_TASK_ID (0x10)
rsp_req
used to request a confirmation
hclass
0
status
0
err_info
0
len
0