dest_stream
The destination stream references which of the CT bus streams is used as a
destination for the data. The parameter takes values in the range 0…31.
dest_slot
The destination slot references the CT bus timeslot to which a local stream
timeslot can be connected or disconnected. The destination slot value has the
same range as the source slot.
pattern
The value of the fixed data to be generated. The value must be in the range 0
to 255. Typical values are 0xff for an "all ones" idle pattern, or 0x2a for an
ITU-T E1 idle pattern.
Status Response
The confirmation message (if requested) indicates success by status of zero.
On error, the following status values can be found in the confirmation
message.
Value Mnemonic Description
0xd2 MVIP_INVALID_STREAM Invalid stream specified in listen request.
0xd3 MVIP_INVALID_TIMESLOT Invalid timeslot specified in listen request.
0xff None Invalid message length.