Dialogic DSI SPCI Network Interface Boards Network Router User Manual


 
7 CONFIGURATION COMMAND Reference
98
Bit 21 is set to 1 for use in Japanese networks; otherwise it must be set to
zero.
All other bits are reserved for future use and must be set to zero.
Note: For ANSI operation bits 8, 9, 10, 11, and 18 must all be set to 1.
7.2.2 MTP Link Set
Syntax: MTP_LINKSET <linkset_id> <adjacent_spc>
<num_links> <flags> <local_spc> <ssf>
Example: MTP_LINKSET 0 321 2 0x0000 456 0x8
Configuration of a link set to an adjacent signaling point.
<linkset_id>
The logical identity of the link set, in the range 0 to one less than the number
of link sets supported, The linkset_id is used in other commands for
reference.
<adjacent_spc>
The signaling point code of the adjacent signaling point.
<num_links>
The number of links to be allocated to the link set.
<flags>
A 16 bit value reserved for future use to specify run time options. Currently
no options are defined so the parameter must be set to zero.
<local_spc>
The signaling point code of the signaling point itself.
<ssf>
The value to be used in the sub-service field of all level 3 messages and
checked for by the discrimination function in all received messages. This is a
4 bit value. Note that for ANSI operation both of the two least significant bits
must be set to 1.
Note: For correct operation the adjacent point code must also appear in a MTP_ROUTE
declaration.
7.2.3 MTP Signaling Link
Syntax: MTP_LINK <link_id> <linkset_id> <link_ref> <slc>
<board_id> <blink> <stream> <timeslot> <flags>
Example: MTP_LINK 0 0 2 2 0 1 0 16 0x0006
Configuration of a signaling link.