Dialogic DSI SPCI Network Interface Boards Network Router User Manual


 
Dialogic
®
DSI SPCI Network Interface Boards Programmer's Manual Issue 5
9
Table 2: Relationship between License Button Codes, Run Modes and Protocol Modules
Button Code
Item Market Name
Description
Maximum Number
of SS7 Links
Run Modes supported
MTP2
MTP3
ISUP-S
ISUP
ISUP-L
TUP-S
TUP
TUP-L
MON
MM SS7SBPCIMONQ Monitoring 4
M3 SS7SBPCIMTPQ MTP 4
T1 SS7SBPCIISTUPSQ ISUP, TUP (Small) 2
T2 SS7SBPCIISTUPQ ISUP, TUP (Regular) 4
T4 SS7SBPCIISTUPLQ ISUP, TUP (Large) 4
2.3.2 Capacity
The figures in the table below indicate the capacity for modules running on
the DSI SPCI Boards.
Table 3: Protocol Dimensioning
Capacity
Run Mode
Maximum
Number of Link
Sets
Maximum
Number of
Routes
Maximum
Number of
Circuit Groups
Maximum
Numbers of
Circuits
MTP3 4 64
ISUP-S 2 64 44 1024
TUP-S 2 64 44 1024
ISUP 4 64 64 2048
TUP 4 64 64 2048
ISUP-L 4 64 128 4096
TUP-L 4 64 128 4096