Emerson MVME2500 Computer Accessories User Manual


 
Controls, LEDs, and Connectors
MVME2500 Installation and Use (6806800L01H)
59
3.5.2 SMT Configuration Switch (S2)
This eight position SMT configuration switch controls the flash bank write-protect, selects the
flash boot image, and controls the safe start ENV settings. The default setting on all switch
positions is "OFF" and is indicated by brackets in Table 3-20.
Figure 3-6 SMT Configuration Switch Position
Table 3-20 Geographical Address Switch Settings
SW2 DEFAULT Signal Name Description Notes
1 OFF (Normal Env) NORMAL_ENV Safe Start ("ON"= Use
normal ENV, "OFF"= Use
safe ENV)
2 OFF (Flash Block A) BOOT_BLOCK_A Boot Block B Select
3 OFF (WP Disabled) FLASH_WP_N SPI Flash Write-Protect
4 OFF (PMC) PMC_XMC_SEL XMC or PMC selection
switch
Will select if XMC card or
PMC card is used
5 OFF (133 MHz) PMC_133 PCI frequency selection