42
Maintenance
Replacing consumables
Replacing the air filter
Replacing the lamp
Resetting the lamp operating time
Dispose of used air
filters properly in ac-
cordance with your
local regulations.
Air Filter:
Polypropylene
Turn off the power, wait
until the projector cools
down and the "beep
beep" tone sounds, then
disconnect the power
cable.
1
2
Remove the air filter
cover.
Put your finger under the
latch and pull it upward.
QTip:
1
2
67
c Caution:
If the lamp stops working
and needs to be re-
placed, there is the dan-
ger that the lamp may
already be broken.
If replacing the lamp of a
projector which has been
installed to the ceiling,
you should always as-
sume that the lamp is
broken and handle it with
extreme care during re-
moval. Furthermore, you
should stand to the side
of the projector, not un-
derneath it.
Turn off the power, wait
until the projector cools
down and the "beep beep"
tone sounds, then discon-
nect the power cable.
* Wait until the lamp cools
down (takes approxi-
mately 1 hour).
Remove the lamp cover.
To remove the cover, use a
screwdriver (the one supplied in
the same package as the option-
al lamp) inserted into the lamp
cover open switch.
Securely tighten the
lamp fixing screws.
Install the lamp cover.
12
The lamp operating time
must always be reset after
the lamp has been replaced
with a new one.
The projector has a built-in
counter which keeps track of
the lamp operating time.
When the cumulative operat-
ing time reaches a certain
point, it causes the replace-
ment warning message to be
displayed.
Press to turn on
the power.
Press to display the