Epson S1C62 Family Computer Hardware User Manual


 
Format
ICE CONTROL SOFTWARE ICS62XX
VIII-40 EPSON S1C62 FAMILY
DEVELOPMENT TOOL REFERENCE MANUAL
Function
FP FILL PROGRAM
#FP,<address 1>,<address 2>,<program data>
Data <program data> is stacked in the program area (ICE emulation memory) at <address 1> to
<address 2>.
Program area (for S1C6S3N7/6S3B7/6S3L7)
000
Address 1 . . . 100
Address 2 . . . 2FF
3FF
Program data Reloads with specified data
#FP,0,3FF,FFB ... Data from addresses 000 to 3FF of the program area
are stacked to the FFB (NOP5 code)
#FP,100,200,FF9 ... When undefined code is detected, an error message is
* COMMAND ERROR * displayed and the instruction will not execute
#FP,200,100,FFF
* COMMAND ERROR * ... Address 1 > address 2 error
#FP,200,200,FFF ...
Address 200 is modified to instruction code FFF (NOP7);
instruction completes normally
#
Examples