Format
ICE CONTROL SOFTWARE ICS62XX
S1C62 FAMILY EPSON VIII-61
DEVELOPMENT TOOL REFERENCE MANUAL
GO TARGET PROGRAM G
#G
#G,<address >
#G,R
Function
■ Display During Execution of GO Instruction
Note: Refer to Section 2.3.4, "Display during run mode and during break" for information on
the display modes.
■ Break Display
#G
*PC=xxxx
*EMULATION END STATUS = BREAK HIT ... (A)
*PC=0100 A=0 B=0 X=70 Y=00 F=ID.C SP=10 ... (B)
*RUN TIME=xxx mS ... (C)
→ The break status is displayed.
(A)BREAK HIT, ESC KEY, BREAK SW displays appear in parts. When the reset switch is
depressed, the message, *ICE6200 RESET SW TARGET*, is displayed without
displaying the break status, and the next instruction is awaited.
(B) Register contents are displayed in part when PC (next executed address) is stopped.
(C) The execution time or executed number of steps set by TIM command are displayed
in part. (Refer to the TIM command.)
1
2
On-the-fly display mode
On-the-fly inhibit mode
Display mode (note) Display methodItem
Sampling of the PC is displayed
about every 500 msec.
HALT message is displayed during halt.
#G
*PC=xxxx...
#G
Exection status is not displayed.