MASK DATA CHECKER MDC62XX
S1C62 FAMILY EPSON IX-3
DEVELOPMENT TOOL REFERENCE MANUAL
C2XXYYYH.HEX ------+
|
C2XXYYYL.HEX ------+
|
C2XXYYYF.DOC ------+------ C2XXYYY.PA0
|
C2XXYYYS.DOC ------+
|
C28XYYYA.DOC ------+
+------ C2XXYYYH.PA0
|
+------ C2XXYYYL.PA0
|
C62XXYYY.PA0 ------+------ C2XXYYYF.PA0
|
+------ C2XXYYYS.PA0
|
+------ C28XYYYA.PA0
Note Don’t use the data generated with the -N option of the Cross Assembler (ASM62XX) as program
data. If the program data generated with the -N option of the Cross Assembler is packed, undefined
program area is filled with FFH code.
In this case, following message is displayed.
WARNING: FILLED <file_name> FILE WITH FFH.
3.2.3 Unpacking of data
In the process of restoring the packed data to the original file, when "2" is selected in the step described in
"Starting MDC62XX", the user is prompted for the input file name as follows:
PLEASE INPUT PACKED FILE NAME (C62XXYYY.PAn) ? C62XXYYY.PA0
When the file name has been entered, the unpacking process is executed and the corresponding file names
are displayed.
C2XXYYYH.HEX ------+
|
C2XXYYYL.HEX ------+
|
C2XXYYYF.DOC ------+------ C2XXYYY.PAn (PACK FILE)
|
C2XXYYYS.DOC ------+
|
C28XYYYA.DOC ------+
PLEASE INPUT PACK FILE NAME (C62XXYYY.PAn) ?
C62XXYYY.PA0
3.2.2 Packing of data
When generating data for submission to Seiko Epson, selecting "1" in the above Section, "Starting
MDC62XX" will prompt for the name of the file to be generated as follows:
The YYY portion is as specified for the user
by Seiko Epson. Moreover, after submitting
the data to Seiko Epson and there is a need
to re-submit the data for reasons such as
faulty programs, etc., increase the numeric
value of "n" by one when the input is made.
(Example: When re-submiting data after
"C62XXYYY.PA0" has been submitted, the pack
file name should be entered as "C62XXYYY.PA1".)
When data is packed, there is need to create ROM data file and option data file in the work disk beforehand.
When the file name has been input, mask data is generated and the corresponding file names are displayed.
With this, the mask file (C62XXYYY.PAn)
is generated. Submit this file to Seiko
Epson.
With this, the mask data file
(C62XXYYY.PAn) is restored to the
original file format, making it possible to
make comparison with the original data.
The restored data file names will be as follows:
• Program data (HIGH side): C2XXYYYH.PAn
(LOW side): C2XXYYYL.PAn
• Option data (function option): C2XXYYYF.PAn
(segment option): C2XXYYYS.PAn
• Melody data (melody ROM, scale ROM, melody option): C28XYYYA.PAn