ICE CONTROL SOFTWARE ICS62XX
VIII-90 EPSON S1C62 FAMILY
DEVELOPMENT TOOL REFERENCE MANUAL
4 ERROR MESSAGE SUMMARY
Error message: * COMMUNICATION ERROR OR ICE NOT READY *
Meaning: ICE is disconnected or power is OFF.
Recovery procedure: Switch OFF the host power supply, connect cable, and reapply power.
Or switch ON power to ICE.
Error message: * TARGET DOWN(1) *
Meaning: Evaluation board is disconnected. (Check at power ON)
Recovery procedure: Switch OFF power to ICE, and connect the evaluation board.
Then, apply power to ICE.
Error message: * TARGET DOWN(2) *
Meaning: Evaluation board disconnected. (Check at command execution)
Recovery procedure: Switch OFF power to ICE, and connect the evaluation board.
Then, apply power to ICE.
Error message: * UNDEFINED PROGRAM CODE EXIST *
Meaning: Undefined code is detected in the program loaded from ROM.
(ICE program terminates)
Recovery procedure: Convert ROM data with the S1C62XXX cross assembler,
then restart the ICE.
Error message: * COMMAND ERROR *
Meaning: A miss occurs by command input.
Recovery procedure: Reenter the proper command.
Error: No response after power on.
Meaning: The ICE-to-HOST cable is disconnected on the host side.
Recovery procedure: Connect the cable.