Chapter 6 Operation Change
6.2 When Changing the Communication Environment
ETERNUS VSS Hardware Provider 2.1 User’s Guide
Copyright 2012 FUJITSU LIMITED P3AM-4582-03ENZ0
48
6.2 When Changing the Communication Environment
When changing the following communication environment settings, change the communication service
(ETERNUS VSS Hardware Provider Communication Server service) operation.
• The IP address of the backup server
• The port number of the backup server
Change the settigs for a backup server first, then a production server as follows.
■ Backup server
● Changing the communication environment setting
• For Windows Server 2008
To start the "Communication Environment Setup command", click the [Start] button – [All Programs]
– [ETERNUS VSS Hardware Provider] – [Communication Environment Setup].
- For a Server Core environment
Execute the "Communication Environment Setup Command".
For details, refer to "8.8
Communication Environment Setup Command (stxvsetcommu)" (page
64).
• For Windows Server 2012
To start the "Communication Environment Setup command", click the [Start] icon – [Communication
Environment Setup].
- For a Server Core environment
Execute the "Communication Environment Setup Command".
For details, refer to "8.8
Communication Environment Setup Command (stxvsetcommu)" (page
64).
● Changing the firewall settings
Remove the changed port number from the firewall targets.
● Restarting the ETERNUS VSS Hardware Provider Communication Server service
When a port number was changed, restart the ETERNUS VSS Hardware Provider Communication
Server service.
Restart it using one of the following procedures.
- Reboot the backup server
- Restart the ETERNUS VSS Hardware Provider Communication Server service in the [Service]
window of the backup server.