Fujitsu fi-6130 Scanner User Manual


 
fi-6130 / fi-6230 Image Scanner Operator's Guide
TROUBLESHOOTING
CONTENTS MAP
TOP
6.3 Remedying Typical Troubles
Symptom: The scanned images are elongated when scanned from the ADF.
Back
Are the rollers dirty?
YES
Clean the dirty rollers.
(For how to clean the rollers, see Section "
4.3
Cleaning the ADF.")
NO
Is any of consumables (Pick rollers and Brake
rollers) worn out?
YES
Check the consumables counters. Replace the
consumables, if needed.
(For how to replace the consumables, see
Chapter "
5 REPLACING CONSUMABLES.")
NO
Have you adjusted the scan scale?
NO
Display the properties of the scanner that you
are using on "Scanners and Cameras" in the
control panel, then adjust the scan scale.
YES
Check the items in Section "6.4 Items to
Check Before Contacting the Dealer Where
You Bought the Scanner" and contact the
dealer or an authorized FUJITSU scanner
service provider.
All Rights Reserved. Copyright 2007 © PFU LIMITED