Appendix A: Logs www.gateway.com
94
POST failure logs
These events indicate that the autoloader or tape drive detected a failure when
power was applied. POST may have failed during a reset and retry.
Important
This event type only indicates each time
the test ran and experienced the error
condition.
:
11/00 Unrecoverable Read Error. After
exhausting the read recovery algorithms,
the drive was not able to read the data
correctly.
Problem may be the tape cartridge or the drive.
If the problem continues, contact customer support.
14/00 Entity Not Found. A logical block that was
written on the tape was not found while
trying to read the data.
Problem may be the tape cartridge or the drive. Check drive
logs to correlate events that may have led up to this
condition.
If the problem continues, contact customer support.
47/00 SCSI Parity Error. SCSI bus
communications problem.
Check SCSI cables, terminators, and all devices attached to
the SCSI bus.
80/01 Cleaning Required. The drive has
detected a condition in which a cleaning
tape must be used.
Use a cleaning tape or different media. Check drive logs to
review related events. If this persists with multiple media
after cleaning, the drive may need to be replaced. If related
to a single piece of media, replace that tape cartridge.
If the problem continues, contact customer support.
ASC/ASCQ Description Suggested Action
Field Description
Last Fail The type of failure that was experienced.