HP (Hewlett-Packard) 1761-NET-ENI Network Card User Manual


 
Publication 1761-UM006A-EN-P - February 2001
4-10 ENI Configuration (Node 248 to 254)
ENI Configuration
Parameters
The following table shows the functions that nodes 248 to 255
perform and their default values. Descriptions of each function can be
found following the table.
These parameters are described in more detail in the following
sections.
Node Function Data Type Number of
Elements
Options Default
248
Save/Reset
(1)
Integer 1 0 = save configuration to flash
1 = simple reset
2 = reset to factory defaults
3 = conditional reset
n/a
249 From String ASCII String 1 ENI Identifier
ENI0.0.0.0@eni1761.org
(2)
250 TCP/IP Configuration Integers 4, 8, 12, 16, or 20 TCP/IP Parameters 000.000.000.000
251 E-Mail Server Integers 4 E-Mail Server Address 000.000.000.000
252 BOOTP Configuration Integer 1 0 = BOOTP configuration
1 = soft configuration
0
253
Baud Rate
(3)
Integer 1 See page 4-16.
Autobaud enabled
(4)
254 Ethernet Hardware Address ASCII String 1 Factory Value Factory Value - Read Only
(see nameplate on unit)
255 Reserved
(1) See page 4-11 for more information on Save/Reset.
(2) The ENI address, “0.0.0.0” will be replaced by the IP address assigned to the ENI. For example, the string may be ENI191.225.181.52@eni1761.org. If the ENI does not
have an assigned IP address, the string will be read as ENI0.0.0.0@eni1761.org.
(3) Changes to the Baud Rate take effect when the ENI power is cycled, or the configuration is saved to flash.
(4) Autodetect of CRC/BCC also occurs when autobaud is selected.