HP (Hewlett-Packard) AA-RS2JA-TE Switch User Manual


 
edge switch 2/16 service manual 2–75
Diagnostics
Did service of the HBAs solve the problem?
NO YES
Exit MAP.
Contact the next level of support. Exit MAP.
24
The switch and attached fabric device are performing a Fibre Channel link reset. This
is a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO YES
The Fibre Channel link and switch appear operational.
Go to step 4.
25
A link incident message appeared in the Link Incident Log or in the Link Incident field
the Port Properties dialog box.
Clear the link incident for the port.
a. At the Hardware View, right-click the port graphic. A pop-up menu appears.
b. Select Clear Link Incident Alert(s). The Clear Link Incident Alert(s) dialog box
displays.
c. Select the This port (n) only radio button (where n is the port number) and click
OK. The link incident clears.
d. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO