Event Code: 202
Message: Power supply thermal failure.
Severity: Major.
Explanatio
n:
The thermal sensor associated with a power supply indicates an overheat condition that
shut down the power supply. The second power supply assumes the full operating load
for the switch.
Action: Replace the failed power supply. Perform the data collection procedure and return the
Zip disk and failed power supply to Hewlett Packard support personnel.
Event
Data:
No supplementary data included with this event.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
444444
Event Code: 203
Message: Power supply AC voltage recovery.
Severity: Informational.
Explanatio
n:
AC voltage recovered for the power supply. Both power supplies adjust to share
operating load for the switch.
Action: No action required.