HP (Hewlett-Packard) AA-RS2JA-TE Switch User Manual


 
edge switch 2/16 service manual B–5
Event Codes
Event Code: 051
Message: Management Server database invalid.
Severity: Minor.
Explanatio
n:
Following an IML, or firmware download, the Management Server database failed its
CRC validation. All Management Services databases are initialized to an empty state,
resulting in an implicit logout of all devices logged in to the Management Server.
Action: Perform the data collection procedure and return the Zip disk to Hewlett Packard
support personnel.
Event
Data:
No supplementary data included with this event.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
44444
Event Code: 052
Message: Management Server internal error.
Severity: Informational.
Explanatio
n:
An operating error (internal to the switch) was detected by the Management Server
subsystem.
Action: Perform the data collection procedure and return the Zip disk to Hewlett Packard
support personnel.
Event
Data:
No supplementary data included with this event.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
44