NetApp Filers Event Codes
10 Storage Management Appliance Software Event Code Definitions Application Notes
124 880E007C 5 The NVRAM battery is fully discharged.
125 880E007D 4 The charge in the NVRAM battery is low.
126 880E007E 5 A node in a Cluster FailOver configuration failed. Its partner
will assume service for the failed node.
127 880E007F 5 The partner has taken over for a failed cluster node.
128 880E0080 2 A cluster node has resumed operation.
129 880E0081 5 At least one volume is more than 98 percent full.
130 880E0082 4 At least one volume is more than 95 percent full.
131 880E0083 2 All volumes are now under 95 percent full.
132 880E0084 7 System temperature is too high to continue operating. The
system is shutting down.
133 880E0085 4 System temperature is too high and in the warning level.
134 880E0086 2 System temperature has returned to an acceptable value.
135 880E0087 5 A disk storage shelf reported a fault, probably due to a
problem with drive placement, fans, power, or temperature.
136 880E0088 2 A previously-reported shelf fault is now corrected.
137 880E0089 7 The appliance’s overall status changed to ‘nonRecoverable’,
indicating a problem so severe that the appliance is shutting
down.
138 880E008A 6 The appliance’s overall status changed to ‘critical’, indicating a
problem that needs immediate attention.
139 880E008B 4 The appliance’s overall status changed to ‘nonCritical’,
indicating a problem that needs attention.
140 880E008C 2 The appliance’s overall status returned to normal.
141 880E008D 2 Cold Start.
142 880E008E 2 Warm Start.
143 880E008F 2 Link Down: %1
144 880E0090 2 Link Up: %1
145 880E0091 2 Authorization failure.
146 880e0092 2 EGP Peer down: %1
Table 4: NetApp Filer Event Codes (Continued)
Event ID
Event
Code
Severity Description