HSV Element Manager Event Codes
46 Storage Management Appliance Software Event Code Definitions Application Notes
3332 88030d04 6 d 4 Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is
capable of operating at the loop link rate established by the drive enclosure I/O
module was found to be running at a different rate. This problem was detected
by the Drive Enclosure Environmental Monitoring Unit located in the drive
enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
affected physical disk drive is installed in the drive enclosure bay identified in the
alarm_error_code.field.en field. The Fibre Channel loop on which the problem
was detected is identified by the content of the alarm_error_code.field.ec field as
follows: 4 = loop A 5 = loop B
3379 88030d33 3 d 33 Storage Cell: %1 Event Code: %2 Description: The AC input to a drive enclosure
power supply has been lost. This makes the remaining power supply a single
point of failure. This problem was detected by the Drive Enclosure Environmental
Monitoring Unit located in the drive enclosure identified in the dencl_num field
within the rack identified in the rack_num field. The rack_num field will not be
valid until a future release. The location of the affected power supply (1 or 2) is
identified in the alarm_error_code.field.en field.
3380 88030d34 6 d 34 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply is
improperly installed or missing. This could affect the drive enclosure air flow and
cause an over temperature condition. The operational power supply will
automatically shut down after a short period of time, thereby disabling the drive
enclosure. This condition remains active until either the problem is corrected, or
the operational power supply shuts down, whichever occurs first. This problem
was detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the affected power supply (1 or 2) is identified in the
alarm_error_code.field.en field.
3381 88030d35 6 d 35 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
component has failed. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the affected power
supply (1 or 2) is identified in the alarm_error_code.field.en field.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description