HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
21Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
The HSV Element Manager is an application provided with the Storage Management
Appliance that is used to configure and monitor HSV110 Array Controllers. The HSV
Element Manager generates controller events and management agent events that help users
understand the status of both the manager application and the storage elements.
The Storage Management Appliance supports the HSV MIB version 2.0.
Controller Events
Table 8 shows events generated by the HSV Controller, which are logged in the Storage
Management Appliance Event Log. The Software Component ID (SWC ID) and Event
Number (Evt. No.) codes can be used to correlate events recorded in the Controller Event Log
of the HSV Element Manager with the events logged in the Storage Management Appliance
Event Log.
Table 8: HSV Element Manager Event Codes: Controller Events
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No. Description
100 88030064 3 0 0 Storage Cell: %1 Event Code: %2 Description: recognized Controller event
generated.
256 88030100 2 1 0 Storage Cell: %1 Event Code: %2 Description: During Executive Services
initialization the system time value was set to the value contained in the time field.
The action field contains one of the following codes which describes the condition
that caused the time value to be: 0 = TOY clock unavailable; time reset to default
date and time. 1 = TOY clock time value was less than or equal to the last known
time value previously stored in nonvolatile memory; time reset to default date and
time. 2 = EDC was bad for last known time value previously stored in nonvolatile
memory; time reset to default date and time. 3 = TOY clock not running; time
reset to default date and time. 4 = TOY clock time value believed to be accurate;
time set to TOY clock time value.
257 88030101 2 1 1 Storage Cell: %1 Event Code: %2 Description: The system time value was set to
the value contained in the time field by a call to the EXEC$SET_TIME service. As
part of setting the time in a dual HSV110 controller configuration, the times are
synchronized. The action field contains one of the following codes which
describes the action taken: 0 = The time was set to the time value on this HSV110
controller. 1 = The master HSV110 controller requested the slave HSV110
controller to set it’s time to the time value. 2 = The slave HSV110 controller set the
local time to the time value. 3 = The HSV110 controller’s TOY clock was set to the
time value.
768 88030300 2 3 0 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field has failed in communicating with the Cabinet (Rack) Bus
Interface Controller.
769 88030301 6 3 1 Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified
by the device field has been rendered inoperable. If the flags.quorum_disk flag is
nonzero, the physical disk drive is the Storage System Quorum disk identified in
the quorum_sequence field. If the flags.inq_state flag is nonzero, the content of
the inq_data and capacity fields is valid. If the rss_flags.member_abnormal flag
is nonzero, the content of the member_state field is valid. The rack_num field will
not be valid until a future release.
770 88030302 3 3 2 Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified
in the node_name field will not be used because the maximum number of
physical disk drives already exist in the current Storage System.