HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
28 Storage Management Appliance Software Event Code Definitions Application Notes
1543 88030607 3 6 7 Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service
Descriptor frame sent to a physical disk drive has timed out. The identity of the
physical disk drive is contained in the device field. The Fibre Channel port used
to communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. If the bay field
contains a value other than zero, the location of the physical disk drive is
contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The command issued to the physical disk drive is
contained in th e cmd field. Note that in this case the content of the error field is
undefined.
1544 88030608 2 6 8 Storage Cell: %1 Event Code: %2 Description: An excessive number of link
errors were detected on a HSV110 controller’s Fibre Channel port. The identity
of the affected Fibre Channel port is contained in the cerp_id field. The HSV110
controller internal Fibre Channel port number of the affected Fibre Channel port
is contained in the port field. This is an informational event triggered by the
occurrence of an excessive number of Tachyon chip link status errors detected
within a particular link status error type. The number of occurrences of each link
status error type is contained in a separate type-specific field (e.g.,
loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its
Fibre Channel port’s for excessive link status errors periodicaly.
1545 88030609 6 6 9 Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported numerous failure prediction threshold exceeded errors. The identity of
the physical disk drive is contained in the device field. The Fibre Channel port
used to communicate with the physical disk drive is contained in the cerp_id field.
The HSV110 controller internal Fibre Channel port number used to communicate
with the physical disk drive is contained in the port field. The arbitrated loop
physical address of the physical disk drive is contained in the al_pa field. If the
bay field contains a value other than zero, the location of the physical disk drive
is contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The num_times field is the number of failure
prediction threshol d exceeded errors reported by the physical disk drive in the
previous minute.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description