HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
25Storage Management Appliance Software Event Code Definitions Application Notes
1033 88030409 2 4 9 Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log validation completed successfully. The content of the
cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi
structure show the validated state of the Storage System Termination Event Log.
The meaning of the status value contained in the cinfo.sctelcbi.status field is as
follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1034 8803040a 2 4 a Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log validation failed. The content of the cinfo.sctelcbi.status field, the
cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the
Storage System Termination Event Log at the time of the failure. The meaning of
the status value contained in the cinfo.sctelcbi.status field is as follows: F =
Control block read failed during maintenance verification. 10= Control block
read failed during maintenance verification. 11= Event data block write failed
during maintenance update. 12= Control block write failed during maintenance
completion. 13= Storage System Termination Event Log related send was
unsuccessful or the master found that the Storage System Termination Event Log is
inaccessible. 16= Event data block read failed during retrieval request.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1035 8803040b 2 4 b Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log has been updated with the termination event information obtained
from the HSV110 controller that is not the Storage System Master. The content of
the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi
structure show the updated state of the Storage System Termination Event Log.
The meaning of the status value contained in the cinfo.sctelcbi.status field is as
follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1036 8803040c 6 4 c Storage Cell: %1 Event Code: %2 Description: The Fault Manager on the
Storage System Master received an invalid Event Information Packet from the
remote Fault Manager. The header information from the invalid Event Information
packet is contained in the ainfo.remote_event field.
Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field,
cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and
minfo.sctelmi structure is undefined.
1037 8803040d 2 4 d Storage Cell: %1 Event Code: %2 Description: The Fault Manager operation
was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation
was performed on both HSV110 controllers. If the ainfo.quiesce_type field is
equal to 1, the operation was performed only on the HSV110 controller that is
not the Storage System Master.
Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure,
cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is
undefined.
1038 8803040e 6 4 e Storage Cell: %1 Event Code: %2 Description: An HSV110 controller sent a last
gasp message prior to terminating operation with an indication that the HSV110
controller identified in the lter.terminating_ctrlr field should also terminate
operation.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description