1560 88030618 2 6 18 Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has begun updating its code. Do not power down this drive
enclosure until the code update has completed. The identity of the Drive Enclosure
Environmental Monitoring Unit is contained in the device field. The Fibre
Channel port used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. The location of the
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and
dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the fed_class, alpa, and num_times fields are
undefined.
1561 88030619 2 6 19 Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has completed updating its code. It is now safe to power down
this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring
Unit is contained in the device field. The Fibre Channel port used to
communicate with the Drive Enclosure Environmental Monitoring Unit is
contained in the cerp_id field. The HSV110 controller internal Fibre Channel
port number used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the port field. The location of the Drive Enclosure
Environmental Monitoring Unit is contained in the rack_num and dencl_num
fields. The rack_num field will not be valid until a future release. Note that in this
case the content of the fed_class, alpa, and num_times fields are undefined.
1562 8803061a 6 6 1a Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
exceeded its soft error threshold. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. Note that in this case the content of the fed_class, cdb, and
sense_data fields are undefined.
1563 8803061b 2 6 1b Storage Cell: %1 Event Code: %2 Description: A HSV110 controller now has an
address on the enclosure address bus. The HSV110 controller location has been
identified. The location of the HSV110 controller is contained in the rack_num
and dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the bay, fed_class, alpa, cerp_id, port, and
num_times fields are undefined.