HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
45Storage Management Appliance Software Event Code Definitions Application Notes
3082 88030c0a 2 c a Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has
been reset due to site failover. The following fields are not valid: status, blocks,
vda.
3084 88030c0c 2 c c Storage Cell: %1 Event Code: %2 Description: The specified destination virtual
disk has successfully completed a merge. The following fields are not valid:
status, blocks, vda.
3087 88030c0f 2 c f Storage Cell: %1 Event Code: %2 Description: The specified virtual disk is no
longer failsafe locked. The following fields are not valid: status, blocks, vda, port,
side.
3088 88030c10 2 c 10 Storage Cell: %1 Event Code: %2 Description: The specified destination virtual
disk has been marked for a full copy. The following fields are not valid: status,
blocks, vda.
3089 88030c11 2 c 11 Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a
site failover has taken place. This group is transitioning from a source role to a
destination role. The following fields are not valid: status, blocks, vda.
3090 88030c12 2 c 12 Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a
site failover has taken place. This group is transitioning from a destination role to
a source role. The following fields are not valid: status, blocks, vda.
3092 88030c14 6 c 14 Storage Cell: %1 Event Code: %2 Description: The specified destination DRM
group was not found. The destination group appears to have been deleted by
the user after a site failover, therefore this dangling DRM source group should
likewise be deleted.
3328 88030d00 6 d 0 Storage Cell: %1 Event Code: %2 Description: Unrecognized event reported by
a Drive Enclosure Environmental Monitoring Unit. The event was reported by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The content of the
alarm_error_code field could not be translated into a known event.
3329 88030d01 6 d 1 Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is not
Fibre Channel compatible or cannot operate at the link rate established by the
drive enclosure I/O modules was detected. This problem was detected by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field
during spin up of the physical disk drive installed in the drive enclosure bay
identified in the alarm_error_code.field.en field. The rack_num field will not be
valid until a future release.
3330 88030d02 3 d 2 Storage Cell: %1 Event Code: %2 Description: A physical disk drive is
improperly installed or missing. This could affect the drive enclosure air flow and
cause an over temperature condition. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The affected drive enclosure
bay is identified in the alarm_error_code.field.en field.
3331 88030d03 3 d 3 Storage Cell: %1 Event Code: %2 Description: A physical disk drive was
removed while software-activated drive locking was enabled on a drive enclosure
that does not support drive locking. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The affected drive enclosure
bay is identified in the alarm_error_code.field.en field.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description