HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
30 Storage Management Appliance Software Event Code Definitions Application Notes
1550 8803060e 6 6 e Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit requested a code update but the code update could not be
found, so the update was not performed. The identity of the affected Drive
Enclosure Environmental Monitoring Unit is contained in the device field. The
Fibre Channel port used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. The location of the
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and
dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the al_pa, bay, fed_class and num_times
field is undefined.
1551 8803060f 6 6 f Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure
Environmental Monitoring Unit is able to communicate with a physical disk drive
but this HSV110 controller is unable to communicate with that physical disk drive
on the Fibre Channel bus. The identity of the Drive Enclosure Environmental
Monitoring Unit is contained in the device field. The Fibre Channel port used to
communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The location of the physical
disk drive is contained in the rack_num, dencl_num, and bay fields. The
rack_num field will not be valid until a future release. Note that in this case the
content of the al_pa, fed_class and num_times fields is undefined.
1552 88030610 6 6 10 Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure
Environmental Monitoring Unit is unable to communicate with this HSV110
controller. The Drive Enclosure Environmental Monitoring Unit has either stopped
communicating with the HSV110 controller, or is not connected to the rack. If the
Drive Enclosure Environmental Monitoring Unit is not connected to the rack, then
the location of the Drive Enclosure Environmental Monitoring Unit is unknown. If
the bay field contains a value other than zero, the identity of the Drive Enclosure
Environmental Monitoring Unit is contained in the device field. If the bay field
contains a zero, the content of the device field is undefined. The Fibre Channel
port used to communicate with the Drive Enclosure Environmental Monitoring
Unit is contained in the cerp_id field. The HSV110 controller internal Fibre
Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. If the bay field
contains a value other than zero, the location of the Dr ive Enclosure
Environmental Monitoring Unit is contained in the rack_num and dencl_num
fields. If the bay field contains a zero, the location of the Drive Enclosure
Environmental Monitoring Unit is unknown and the content of the rack_num and
dencl_num fields is undefined. The rack_num field will not be valid until a future
release. Note that in this case the content of the al_pa, fed_class and num_times
fields is undefined.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description