HSV Element Manager Event Codes
51Storage Management Appliance Software Event Code Definitions Application Notes
3509 88030db5 6 d b5 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
current sensor out of range condition has been reported. This problem was
detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the current sensor (1 through 4) is identified in the
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12
VDC The current sensor out of range condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The element current is
approaching, but has not reached, the high current CRITICAL threshold.
Continued operation under these conditions may result in a CRITICAL condition.
2 = The element current is above the high current CRITICAL threshold.
3544 88030dd8 3 d d8 Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane
invalid NVRAM read error has occurred. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the drive
enclosure is the affected element.
3545 88030dd9 6 d d9 Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane
error has occurred. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The alarm_error_code.field.en field
contains the value 1 signifying that the drive enclosure is the affected element.
The cause of the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 11 = Unable to write data to the
NVRAM. This problem prevents communication between elements in the
enclosure. 12 = Unable to read data from the NVRAM. This problem prevents
communication between elements in the enclosure. 13 = NVRAM has not been
initialized properly. This is a manufacturing error.
3549 88030ddd 6 d dd Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module
error has occurred. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the I/O module (A
(01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of
the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The I/O module’s Fibre Channel
link speed is not supported by the backplane. This error prevents the controller
from establishing a link with enclosure drives and eliminates the enclosure
dual-loop capability. 11 = Unable to write data to the I/O module NVRAM. 12
= Unable to read data from the I/O module NVRAM.
3550 88030dde 3 d de Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module is
unable to communicate with the Drive Enclosure Environmental Monitoring Unit.
This problem was detected by the Drive Enclosure Environmental Monitoring Unit
located in the drive enclosure identified in the dencl_num field within the rack
identified in the rack_num field. The rack_num field will not be valid until a future
release. The location of the I/O module (A (01) and B (02)) is identified in the
alarm_error_code.field.en field.