HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
50 Storage Management Appliance Software Event Code Definitions Application Notes
3459 88030d83 6 d 83 Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has experienced a hardware failure. This problem was detected
by the Drive Enclosure Environmental Monitoring Unit located in the drive
enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
3461 88030d85 3 d 85 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
failed to respond to a shut down command. This problem was detected by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
3469 88030d8d 6 d 8d Storage Cell: %1 Event Code: %2 Description: A drive enclosure transceiver
error has been detected. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the transceiver (1
through 4) is identified in the alarm_error_code.field.en field as follows: 1 =
Transceiver 01 2 = Transceiver 02 3 = Transceiver 03 4 = Transceiver 04 The
transceiver error condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The transceivers on this link are
not the same type or they are incompatible with the drive enclosure I/O module.
This error prevents the controller from establishing a link with the enclosure drives
and eliminates the enclosure dual-loop capability. 2 = The transceiver can no
longer detect a data signal. This error prevents the controller from transferring
data on a loop and eliminates the enclosure dual-loop capability. 3 = The
system has detected an FC-AL bus fault involving a transceiver. This error prevents
the controller from transferring data on a loop and eliminates the enclosure
dual-loop capability.
3489 88030da1 6 d a1 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
voltage sensor out of range condition has been reported. This problem was
detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the voltage sensor (1 through 4) is identified in the
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12
VDC The voltage sensor out of range condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The element voltage is
approaching, but has not reached, the high voltage CRITICAL threshold.
Continued operation under these conditions may result in a CRITICAL condition.
2 = The element voltage is above the high voltage CRITICAL threshold. 3 = The
element voltage is approaching, but h as not reached, the low voltage CRITICAL
threshold. Continued operation under these conditions may result in a CRITICAL
condition. 4 = The element voltage has reached the low voltage CRITICAL
threshold.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description