HP StorageWorks and McData Switch Event Codes
11Storage Management Appliance Software Event Code Definitions Application Notes
HP StorageWorks and McData Switch Event Codes
The following events are generated by HP StorageWorks switches and McData switches and
are recorded in the Storage Management Appliance Event Log. Many of these event types
have several possible states and each state has an appropriate severity code.
The Storage Management Appliance supports the following StorageWorks and McData MIB
versions:
V1.9 for the ED-5000 series
V1.10 for the EF-6000 series
V1.0 for the ES-1000 series
Table 5: HP StorageWorks and McData Event Codes
Event
ID
Event
Code
Possible States Severity Description
100 880C0064 N/A 2 An unknown trap event was received.
101 880C0065 online
offline
testing
faulty
unknown
2
5
2
7
0
B_Port Index %2 changed state to %1.%n
A es1000PortBportScn is generated whenever
a B_Port changes its operational state.
102 880C0066 online
offline
testing
faulty
unknown
2
5
2
7
0
H_Port Index %2 changed state to %1.%n
A es1000PortHportScn is generated whenever
a H_Port changes its operational state
103 880C0067 active
updatebusy
failed
unknown
2
2
7
0
Component Code %2 has changed state to
%1.%n
A es1000CompScn is generated whenever a
COMPONENT status changes its operational
state.
104 880C0068 online
offline
testing
faulty
unknown
2
5
2
7
0
Port Index %2 changed state to %1.%n
An ed5000PortScn(1) is generated whenever
a Fc_Port changes its operational state.
105 880C0069 active
backup
updatebusy
failed
unknown
2
3
2
7
0
FRU Code %2 has changed state to %1.%n
An ed5000FruScn(2) is generated whenever a
FRU status changes its operational state.
106 880C006A online
offline
testing
faulty
unknown
2
5
2
7
0
Port Index %2 changed state to %1.%n
An ef6000PortScn(1) is generated whenever a
Fc_Port changes its operational state.
107 880C006B active
backup
updatebusy
failed
unknown
2
3
2
7
0
FRU Code %2 has changed state to %1.%n
An ef6000FruScn(2) is generated whenever a