HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
35Storage Management Appliance Software Event Code Definitions Application Notes
2324 88030914 6 9 14 Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified
in the handle field has transitioned to the FAILED state. The value.ul1 field
contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The
state values that may be found in the value.ul2 fields are as follows: 1 = Normal
2 = Migrating 3 = Missing 4 = Reconstructing 5 = Completing 6 = Reverting
2325 88030915 6 9 15 Storage Cell: %1 Event Code: %2 Description: The state of the HSV110
controller identified in the handle field has transitioned to the FAILED state. The
value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the
old state: 1 (NORMAL).
2327 88030917 6 9 17 Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for
battery assembly ‘1’ located within the HSV110 controller identified in the
handle field has changed from PRESENT to NOT PRESENT indicating that the
battery assembly was removed. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old
state of the Battery Present flag: 1 (PRESENT).
2328 88030918 2 9 18 Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery
assembly ‘1’ located within the HSV110 controller identified in the handle field
has transitioned from the NOT IN USE to IN USE state indicating that the battery
assembly is functioning properly. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of
the Battery In Use flag: 0 (NOT IN USE).
2329 88030919 2 9 19 Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors
located within the HSV110 controller identified in the handle field has reported a
voltage that indicates that a voltage that was previously out of range has returned
to the normal range. The value.ul1 field contains the normal range voltage
value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V,
3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g.,
12.5V is expressed as 12500.
2330 8803091a 3 9 1a Storage Cell: %1 Event Code: %2 Description: The battery assembly voltage
regulator located within the HSV110 controller identified in the handle field is
offline.
2331 8803091b 2 9 1b Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group
identified in the handle field has transitioned to the NORMAL state. The value.ul1
field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field
contains the old Disk Group state. The state values that may be found in the
value.ul2 field are as follows: 2 = Disk Group with no redundancy is inoperative
3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with
mirrored redundancy is inoperative 5 = Disk Group with no redundancy is
inoperative, marked for re-use 6 = Disk Group with parity redundancy is
inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is
inoperative, marked for re-use
2332 8803091c 2 9 1c Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level for
the Disk Group identified in the handle field has returned to the normal range.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description