HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
26 Storage Management Appliance Software Event Code Definitions Application Notes
1536 88030600 6 6 0 Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported that it has exceeded its failure prediction threshold. The identity of the
physical disk drive is contained in the device field. The Fibre Channel port used
to communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. If the bay field
contains a value other than zero, the location of the physical disk drive is
contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The command issued to the physical disk drive is
contained in t he cmd field. The sense data obtained from the physical disk drive
as a result of the failure prediction threshold exceeded error is contained in the
error field.
1537 88030601 3 6 1 Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the
HSV110 controller has failed to respond. The identity of the affected Fibre
Channel port is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number of the affected Fibre Channel port is contained in the
port field. The peb array contains the port event block information. The
peq_frz_prod_index field contains the index to the port event block in use when
the Tachyon chip entered the frozen state. The peq_prod_index field contains the
index to the next port event block. The peq_cons_index field contains the index
to the next port event block to be acted upon. The failure_cause field contains the
internal routing.
1538 88030602 2 6 2 Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported a check condition error. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. The Fibre Channel Exchange Descriptor class is contained in the
fed_class field. The command issued to the physical disk drive is contained in the
cmd field. The sense data obt ained from the physical disk drive as a result of the
check condition error is contained in the error field.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description