HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
23Storage Management Appliance Software Event Code Definitions Application Notes
1027 88030403 6 4 3 Storage Cell: %1 Event Code: %2 Description: An unexpected event occurred
while a termination event was being processed. The value contained in the
uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event
code. 1 = Power failure before initialization could complete. 2 = Recursive
termination before initialization could complete. 3 = Terminated during the first
part post-termination preparation. 4 = Terminated during the load of the G3
Glue registers. 5 = Terminated during the second part post-termination
preparation. 6 = Terminated during event report block load. 7 = Terminated
during initialization of all hardware components and software data structures in
preparation for restart. 8 = Terminated during execution of an unrecognized
post-termination operation (premature). 9 = Power failure during execution of a
post-termination operation. A = No good entries found in Termination Event
Array. B = The EDC of one or more Termination Event Array entries is bad. C =
Terminatio n Event Array entry control block revision is different. D = Termination
Event Array entry information block revision is different. E = Termination Event
Array entry up time value is greater than the system’s up time value. F =
Termination Event Array entry up time value is less than the previous entry’s up
time value. 10= Termination Event Array entry sequence number value is less
than the previous entry’s sequence number value. 11= Detected an unrecognized
dump/restart control code. 12= Failed to terminate the entity dump loop. 13=
Unexpected dump entity size. 14= Unexpected Event Log Packet processing stage
code. 15= Number of Termination Parameters supplied not equal to maximum
allowed as required. The post-termination operation being performed at the time
the unexpected event occurred is contained in the uei.pto field.
Note: The lteihd and lter fields may not describe the event that caused the
HSV110 controller to terminate operation depending on how far t ermination
processing got before the unexpected event occurred.
1028 88030404 2 4 4 Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log
validation completed successfully. The content of the cinfo.scelcbi.status field, the
cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of
the Storage System Event Log. The meaning of the status value contained in the
cinfo.scelcbi.status field is as follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi
structure is undefined.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description