HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
HSV Element Manager Event Codes
52 Storage Management Appliance Software Event Code Definitions Application Notes
3564 88030dec 3 d ec Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module
invalid NVRAM read error has occurred. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The location of the I/O
module (A (01) or B (02)) is identified in the alarm_error_code.field.en field.
3568 88030df0 2 d f0 Storage Cell: %1 Event Code: %2 Description: The status has changed on one or
more of the drive enclosures. This is an informational event triggered by the
occurrence of a change in the status of a drive enclosure. The content of the
alarm_error_code field, drive enclosure, and rack number have no meaning for
this event.
16896 88034200 2 42 0 Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel
port transitioned to link down.
16897 88034201 2 42 1 Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel
port transitioned to link failed.
16899 88034203 2 42 3 Storage Cell: %1 Event Code: %2 Description: An excessive number of link
errors were detected on a Fibre Channel port. The error counters are checked
every hour. This is an informational event that reports all link status errors
detected by the Tachyon chip, triggered by an excessive number detected in one
category.
16900 88034204 3 42 4 Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the
HSV110 controller has failed to respond. The evt_peq.peb field contains port
event information. The evt_peq.peq_frz_prod_index field contains the index to
the port event block that points to when the Tachyon chip entered the frozen state.
The evt_peq.peq_prod_index field contains the index to the next port event block.
The evt_peq.peq_cons_index field contains the index to the next port event block
to be acted upon.
33536 88038300 6 83 0 Storage Cell: %1 Event Code: %2 Description: A failure was detected during the
execution of this HSV110 controller’s on board diagnostics.
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev-
erity
SWC
ID
Evt.
No.
Description