HP (Hewlett-Packard) hp OpenView storage management appliance software Computer Accessories User Manual


 
NetApp Filers Event Codes
9Storage Management Appliance Software Event Code Definitions Application Notes
NetApp Filers Event Codes
The following events are generated by NetApp Filer devices and are recorded in the Storage
Management Appliance Event Log. A number of these events are associated with user-defined
traps and most indicate a condition that is likely to have a negative impact on operations. A
small number of events mark a return to normal operation after some period of abnormal
operation.
The Storage Management Appliance supports the NetApp MIB version 1.2.
Table 4: NetApp Filer Event Codes
Event ID
Event
Code
Severity Description
100 880E0064 2 An unknown trap event was received.
101 880E0065 3 A polling-style trap built by the user using the SNMP traps
command on the filer.
102 880E0066 5 Disk Health Monitor reported a Disk Degraded-I/O Event.
103 880E0067 4 Disk Health Monitor reported a Disk Predictive-Failure Event.
104 880E0068 7 A user-defined trap indicating an extremely urgent situation,
usually indicating that the system has failed and is shutting
down.
105 880E0069 5 A user-defined trap indicating a condition that should be
corrected immediately, such as a failed disk.
106 880E006A 6 A user-defined trap indicating a critical condition, such as a
hard device error.
107 880E006B 5 A user-defined trap indicating an error condition, such as a
mistake in a configuration file.
108 880E006C 4 A user-defined trap indicating a condition which is not an error,
but which may require special handling.
109 880E006D 2 A user-defined trap meant to provide information, such as an
hourly uptime message.
110 880E006E 1 A user-defined trap used for debugging purposes.
111 880E006F 7 System is shutting down because the system has been running
in degraded mode for 24 hours.
112 880E0070 5 One or more disks failed.
113 880E0071 2 The failed disks have been repaired.
114 880E0072 7 Critical chassis or cpu fans have failed and the system is
shutting down.
115 880E0073 5 One or more chassis fans failed.
116 880E0074 3 One or more chassis or cpu fans are in warning state.
117 880E0075 2 All fans are repaired.
118 880E0076 7 Critical power supplies or power rails failed and the system is
shutting down.
119 880E0077 5 One or more redundant power supplies failed.
120 880E0078 3 One or more power supplies or power rails in warning state.
121 880E0079 2 Previously-failed power supplies or power rails have been
repaired.
122 880E007A 4 CPU utilization exceeds 90 percent.
123 880E007B 2 CPU utilization has dropped back below 90 percent.