Hitachi MK-90RD011-25 Computer Drive User Manual


 
120 Chapter 3 Preparing for CCI Operations
3.1.2 Using CCI with Hitachi and Other RAID Storage Systems
Table 3.9 shows the related two controls between CCI and the RAID storage system type
(Hitachi or HP
®
XP). Figure 3.1 shows the relationship between the APP, CCI, and RAID
storage system.
The following common API/CLI commands are rejected with EX_ERPERM(*1) by
connectivity of CCI with RAID storage system:
horctakeover, paircurchk, paircreate, pairsplit, pairresync, pairvolchk, pairevtwait,
pairdisplay, raidscan (except -find option only), raidar, raidvchkset, raidvchkdsp,
raidvchkscan
The following XP API/CLI commands are rejected with EX_ERPERM(*2) on HITACHI
storage system even when both CCI and Raid Manager XP (provided by HP) are installed:
pairvolchk -s, pairdisplay -CLI, raidscan -CLI, paircreate -m noread for TrueCopy,
paircreate -m dif/inc for ShadowImage
Table 3.9 Relationship between CCI and RAID Storage System
CCI Version Installation RAID System Common API/CLI XP API/CLI
CCI 01-08-03/00 or higher CCI Hitachi Enable
HP
®
XP EX_ERPERM(*1)
CCI and Raid Manager XP
Hitachi Enable
HP
®
XP Enable
Cannot use
(except CLI)
Raid Manager XP HP
®
XP Enable Enable Raid Manager XP
01.08.00 or higher
(provided by HP
®
)
Hitachi EX_ERPERM(*1) EX_ERPERM(*2)
Raid Manager XP and CCI HP
®
XP Enable Enable
Hitachi Enable EX_ERPERM(*2)