Hitachi MK-90RD011-25 Computer Drive User Manual


 
294 Chapter 4 Performing CCI Operations
Parameter Value
Returned values When the -nowait option is specified:
Normal termination: 0: The status is NOWAIT.
Abnormal termination: other than 0 to 127, refer to the execution logs for error details.
When the -nowait option is not specified:
Normal termination: 0: The status is DONE (completion of synchronization).
1: The status is TIMEOUT (timeout).
2: The status is BROKEN (Q-marker synchronized process is rejected).
3: The status is CHANGED (Q-marker is invalid due to resynchronize).
Abnormal termination: other than 0 to 127, refer to the execution logs for error details.
Restriction Specified <group> volume must be PVol with status PAIR. Other cases reply with error (EX_INVVOL). It is
possible to issue pairsysncwait from SVOL side with -m <marker>.
Table 4.49 Specific Error Code for Pairsyncwait
Category Error Code Error Message Recommended Action Value
Volume status
Unrecoverable
EX_INVVOL Invalid volume status Confirm pair status using pairdisplay -l. 222
Note: Unrecoverable errors are fixed and will not be resolved, even after re-executing the
command. If the command failed, the detailed status will be logged in the CCI command log
($HORCC_LOG) (see Table A.2), even if the user script has no error handlin
g.