Hitachi MK-90RD011-25 Computer Drive User Manual


 
132 Chapter 3 Preparing for CCI Operations
New installation. To install the CCI software on an OpenVMS
®
system:
1. Insert and mount the provided CD or diskette.
2. Execute the following command:
$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -
_$ /destination=SYS$POSIX_ROOT:[000000]
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists
3. Verify installation of the proper version using the raidqry command:
$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
4. Follow the requirements and restrictions in section 3.5 for porting for OpenVMS.
Versi
on update. To update the CCI software version on an OpenVMS
®
system:
1. Perform the update after making sure that HORCM is not in operation:
$horcmshutdown for one HORCM instance
$horcmshutdown 0 1 for two HORCM instances
When a command is being used in interactive mode, terminate it using the “-q” option.
2. Insert and mount the provided CD or diskette.
3. Execute the following command:
$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists
4. Verify installation of the proper version using the raidqry command:
$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
5. Follow the requirements and restrictions in section 3.5 for porting for OpenVMS.