Error code/symptom FRU/action
00180xxx (PCI adapter has requested
resources that are not available)
1. Reorder adapters in PCI slots.
2. Verify that boot device is positioned early in the scan order so that it
is executed by POST.
3. Verify that all adapters are set correctly in Configuration/Setup Utility
program, changing memory settings if necessary.
4. Remove an adapter to make more memory available to the adapters.
5. Disable adapter BIOS on adapter (see documentation provided with
adapter).
6. System board.
00181000
(General PCI error)
1. Adapter
2. System board
012980xx (Microprocessor 1 error)
1. Verify both microprocessors have same cache size and type
and the same clock speed.
2. Download and update the BIOS code.
3. Microprocessor 1.
4. System board.
012981xx (Microprocessor 2 error)
1. Verify both microprocessors have same cache size and type
and the same clock speed.
2. Download and update the BIOS code.
3. Microprocessor 2.
4. System board.
I9990301
(Invalid boot record on hard disk)
1. Partition and format hard disk drive.
2. Cable.
3. Hard disk drive.
4. Adapter/system board.
I9990650
(AC power has been restored)
1. Check cable.
2. Check for interruption of power.
3. Power cable.
Diagnostic error codes
Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a
FRU. The description for these error codes are:
000 The test passed.
195 The Esc key was pressed to abort the test.
197 Warning; a hardware failure might not have occurred.
For all error codes, replace or follow the indicated FRU or action.
Error code/symptom FRU/action
001-XXX-000 (Failed core tests)
v System board
001-XXX-001 (Failed core tests)
v System board
90 IntelliStation Z Pro Types 6223 and 6227: Hardware Maintenance Manual and Troubleshooting Guide